abap news
Home » Test Date-Dependent ABAP Code with an Injected Clock

Test Date-Dependent ABAP Code with an Injected Clock

ABAPBy xabap Published
A clock plugged into a program component

Code that reads sy-datum gives a different result every day, so a test that passes today may fail tomorrow. Put the date behind a small interface and pass it to the class. In the test you hand in a fixed date.

1. The clock

INTERFACE lif_clock.
  METHODS today RETURNING VALUE(rv_date) TYPE d.
ENDINTERFACE.

CLASS lcl_system_clock DEFINITION FINAL.
  PUBLIC SECTION.
    INTERFACES lif_clock.
ENDCLASS.

CLASS lcl_system_clock IMPLEMENTATION.
  METHOD lif_clock~today.
    rv_date = cl_abap_context_info=>get_system_date( ).
  ENDMETHOD.
ENDCLASS.

cl_abap_context_info is released for ABAP Cloud. In classic ABAP you can use sy-datum, or sy-datlo if you mean the user’s local date.

2. The code that needs a date

CLASS lcl_invoice DEFINITION FINAL.
  PUBLIC SECTION.
    METHODS constructor
      IMPORTING io_clock TYPE REF TO lif_clock OPTIONAL.
    METHODS is_overdue
      IMPORTING iv_due_date       TYPE d
      RETURNING VALUE(rv_overdue) TYPE abap_bool.
  PRIVATE SECTION.
    DATA mo_clock TYPE REF TO lif_clock.
ENDCLASS.

CLASS lcl_invoice IMPLEMENTATION.
  METHOD constructor.
    IF io_clock IS BOUND.
      mo_clock = io_clock.
    ELSE.
      mo_clock = NEW lcl_system_clock( ).
    ENDIF.
  ENDMETHOD.

  METHOD is_overdue.
    rv_overdue = xsdbool( iv_due_date < mo_clock->today( ) ).
  ENDMETHOD.
ENDCLASS.

The parameter is optional, so existing callers do not change.

3. The tests

CLASS ltd_fixed_clock DEFINITION FINAL FOR TESTING.
  PUBLIC SECTION.
    INTERFACES lif_clock.
    METHODS constructor IMPORTING iv_date TYPE d.
  PRIVATE SECTION.
    DATA mv_date TYPE d.
ENDCLASS.

CLASS ltd_fixed_clock IMPLEMENTATION.
  METHOD constructor.
    mv_date = iv_date.
  ENDMETHOD.
  METHOD lif_clock~today.
    rv_date = mv_date.
  ENDMETHOD.
ENDCLASS.

CLASS ltc_invoice DEFINITION FINAL
  FOR TESTING RISK LEVEL HARMLESS DURATION SHORT.
  PRIVATE SECTION.
    METHODS due_today_is_not_overdue FOR TESTING.
    METHODS due_yesterday_is_overdue FOR TESTING.
    METHODS year_end_is_handled FOR TESTING.
ENDCLASS.

CLASS ltc_invoice IMPLEMENTATION.
  METHOD due_today_is_not_overdue.
    DATA(lo_invoice) = NEW lcl_invoice( NEW ltd_fixed_clock( '20260301' ) ).
    cl_abap_unit_assert=>assert_false( lo_invoice->is_overdue( '20260301' ) ).
  ENDMETHOD.

  METHOD due_yesterday_is_overdue.
    DATA(lo_invoice) = NEW lcl_invoice( NEW ltd_fixed_clock( '20260301' ) ).
    cl_abap_unit_assert=>assert_true( lo_invoice->is_overdue( '20260228' ) ).
  ENDMETHOD.

  METHOD year_end_is_handled.
    DATA(lo_invoice) = NEW lcl_invoice( NEW ltd_fixed_clock( '20260101' ) ).
    cl_abap_unit_assert=>assert_true( lo_invoice->is_overdue( '20251231' ) ).
  ENDMETHOD.
ENDCLASS.

The boundary is now explicit: an invoice due today is not overdue. If somebody changes < to <=, the first test fails.

When is this worth it?

Use it where a date decides something: deadlines, validity, period ends. For a simple “created on” field, reading the system date directly is fine. The same pattern works for the current time, random numbers and the user name.

Source: SAP ABAP cheat sheets: ABAP Unit